EN
110
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE ACTION
The appliance does not
start when the power
switch is pressed.
Error code P1 (full bottom tray) is
shown on the display).
ð
Empty the bottom tray.
The room temperature is lower
(cooling) or higher (heating) than
the set point temperature.
ð
Change the set point temperature.
The appliance does not
produce enough cooling.
Windows or doors open.
ð
Close all the doors and windows.
Source of heat in the room.
ð
Remove sources of heat if possible.
Outlet hose blocked or not con-
nected.
ð
Connect the hose and arrange it so
that it works properly.
Set point temperature too high.
ð
Set a lower set point temperature.
Air lter blocked.
ð
Clean the air lter.
Noise or vibration. Surface is uneven or not level.
ð
Put the appliance on a smooth,
horizontal surface.
Gurgling sound.
Caused by refrigerant in the
appliance.
ð
This is quite normal.
The appliance switches
o in heating mode.
The overheating protection trips
when the outgoing air temperature
is higher than 70°C.
ð
Allow the appliance to cool and
restart it.