• Do not expose the appliance to strong or harmful chemicals.. Do not use the appliance in explosive
environments, e.g. in the vicinity of ammable liquids, gases or dust, or in environments that contain
toxic or harmful substances.
• Do not leave children unsupervised in the vicinity of the appliance when it is switched on.
• The appliance must only be used as it is intended to be used and in accordance with these instructions.
• Do not use the product in explosive environments, e.g. in the vicinity of ammable liquids, gas or dust.
• Do not use an extension cord or plug adapter, or the equivalent. Never modify the plug in any way.
• Check that the mains voltage corresponds to the rated voltage on the type plate.
• The plug must be plugged into a correctly installed earthed mains socket. Never modify the plug in any
way. If the plug does not t the mains socket, contact an authorised electrician to install an earthed
mains socket.
• The mains socket should be easily accessible.
NOTE: The data on the type plate has been measured on installation without an extended outlet duct and
without accessories.
TECHNICAL DATA
Voltage 230 VAC
Dehumidifying capacity 28.8 l/24 hours
EER 2.6
Output 1600 W
Cooling power 3500 W
Cooling capacity 12249 BTU/hour
Energy class A
Cord length 1.1 m
Refrigerant R410A (410 g)
Noise level 65 dB
Air ow 386 m
3
/hour
Temperature range 17 to 35°C
Dimensions W520xH880xD440 mm
Weight 32.5 kg