Before proceed, make sure the X axis is leveled (Fig. 10), in case X axis lost its balance
during shipping or due to other unexpected causes. A rule or maybe caliper or anything
with certain length can be used for this measure. The Z lead screw can be turned
manually for adjust the levelness of the X axis (wear gloves).
(Figure 10)
2. Fig. 11, on the Home Menu, Click Tools-->Home-->Home All.
After Home All, it is suggested to visually check again if the X axis is leveled or not. If
adjustment needed, you may have to click Setup-->Motor to disable the motor
so the Z lead screws could be turned manually for height adjusting. After adjustment,
click Home All again for the next steps.