AP Diving Ltd. APV200 Inflator Maintenance Manual
Page 21 of 30
- Massage this grease all around the bag until it is evenly distributed over the inside
surface area.
- Take the O-rings to be greased out of their storage container, either using gloves or
using an O2-cleaned instrument like a dentist hook.
- Drop them in the grease bag, and from the outside of the bag move them around with
your fingers, making sure they get in full contact with the grease.
- Open the bag, and using a clean instrument like a dentist hook, take the now properly
greased O-rings out.
- Inspect them to make absolutely sure that the grease is evenly and lightly distributed on
the O-rings and that there are no areas of excess grease - no globs or strands.
- Fit them where they belong on your diving equipment, still making sure not to touch them
with your bare hands.