AP Diving Ltd. APV200 Inflator Maintenance Manual
Page 9 of 30
3.2 Special Tools needed
When servicing the APV200 inflator, the following special tool is needed:
AP50E
3.3 Standard Tools needed
Besides the special tools mentioned above, there are no special tools needed for servicing
the APV200 inflator gas isolator.
Normal tools needed are:
- Pliers;
- O-ring picking tools;
- Oxygen-compatible or Silicon grease (depending on the gas the inflator is exposed to)
o see chapter 5 for remarks about when you need to keep this device in oxygen
service;
- (Access to) an ultrasonic bath for cleaning the metal parts.
WARNING: Do NOT use aggressive chemicals. They might damage the metal plating of
the APV200 inflator. Use an ultrasonic cleaning bath with a suitable cleaning fluid.
A very good cleaning fluid is Biox “O2” immersion fluid. See WWW.BIOXINT.COM for further
information and distributors.
The use of rubber gloves while re-assembling the APV200 inflator is recommended to avoid
rendering the APV200 inflator oxygen unclean due to human touch.