57
TC5-2V2SA.rev.05
TC5-2V2SA
NOTES:
i) These initial parameter settings will not be retained in the controller's
memory. Each new setting will replace the preceding one.
ii) If the power supply is cut off, the last parameter settings will be re-
tained in memory until the power is restored.
PARAMETER
FACTORY
SETTING
RANGE OF
VALUES
Mist
Time On 1 minute
0 to 60 minutes,by
increments of 1
minute
Time Off 10 minutes
0 to 60 minutes,by
increments of 1
minute
Offset 14°F (7.8°C)
0.5 to 40
o
F
(0.3 to 22.2
o
C)
Differential 2
o
F(1.1
o
C)
0.5 to 20
o
F
(0.3 to 11.1
o
C)
Humidity Turn
Off Level
95% 40 to 100%
Heater Offset 2.0
o
F (1.1
o
C)
-10 to 20
o
F
(-5.7 to 11.1
o
C)
Max. Temperature Diff.
Between Zones
7.5°F(4.2°C)
5 to 40°F
(2.8 to 22.2°C)
Alarms
High Offset 12.0
o
F(6.7
o
C)
0.5 to 40
o
F
(0.3 to 22.2
o
C)
Low Offset 10.0
o
F(5.6
o
C)
0.5 to 40
o
F
(0.3 to 22.2
o
C)