4. System Preventive Maintenance
For Apeks System Manuals and Other Component Manuals visit http://www.apekssupercritical.com/apeks-
supercritical-operation-manuals/
Included with each system is a small squeeze bottle to help with proper maintenance and cleaning of your
systems C0
2
lines. Ethanol (200 proof) is a typical and acceptable cleaning agent. Please label the bottle
accordingly.
4.1. Extraction System Maintenance (Extractor and Separator Stands)
Frequency
Maintenance Item
After Each
Extraction
Remove extracted oil from collector cup and separator walls, clean walls and
cup with alcohol.
Check separator 2 for oil carryover and clean if necessary.
Inspect separator gaskets and grooves prior to reassembly.
Clean piping between separator 1 and 2 with alcohol.
Clean Separator 2 CO
2
outlet to separator filter.
Remove spent material from the extraction vessel by vacuuming it out through
the top flange.
Verify the extractor filters are clear and free of debris
Check extraction vessel O-rings and O-rings groove sealing surfaces for
damage replace if necessary
Inspect the surfaces on Extraction vessel to make sure they are free from dust
and debris. Failure to clean surfaces properly can cause vessel not to seal
properly or damage to the cup seal.
Every 80
Hours
Run the system “empty of plant material” for 1 hour to clean the high-pressure
side of the system and extraction vessel(s)
Yearly
Check torque on all screws in electrical panels (see Appendix D)
Resource
Apeks online store
http://www.apekssupercritical.com/online-store/
4.2. Diaphragm Compressor Maintenance
See Diaphragm Compressor Manual for specific instructions on maintenance items. Below is general system
information
Frequency
Maintenance Item
Daily
Check oil level
Check oil pressure
Listen for abnormal noise or vibration
Check Leak Detection System status
Every 500
Hours
Clean/Change Separator Filter.
Check belt tension (See Appendix B)
Clean process check valves.
Every 1500
Hours
Preform regular oil change.
Check torque on all screws in electrical panels (see Appendix D)