Apeks Supercritical The Duplex™ Operation Manual
39
Revision Date 8/28/2018
Appendix D.
Electrical Screw Torque Requirements
a) Fuse Holders (1492-H6) = 7.1 lb-in
b) Power Supply (1606-XLE120E) – 7 lb-in
c) Terminal Blocks (1492-J4) = 9 lb-in
d) Ground Blocks (1492-JG4) = 9 lb-in
e) Ground Block Middle Screw (1492-JG4) = 7.1 lb-in
f) JG10 Large Ground Blocks (1492-JG10) = 20.4 lb-in
g) JG10 Large Ground Block Middle Screw (1492-JG10) = 8.9 lb-in
h) Small Motor Contactor Phillip Screws (100-C55D10) = 31 lb-in
i) Small Motor Contactor (43-44) Phillip Screws = 13 lb-in
j) Overload Relay (T1/T2/T3) Phillip Screws = 22 lb-in
k) Overload Relay (95-98) Phillip Screws = 5 lb-in
l) Large Motor Contactor Allen Screws (100-C72D10) = 53 lb-in
m) Large Motor Contactor Phillips Screws (100-C72D10) = 13 lb-in
n) Overload Relay Allen Screws (193-EEGE) = 40 lb-in
o) Overload Relay Phillips Screws (192-EEGE) = 5 lb-in
p) Micro 850 Power Supply = 4.4 lb-in
q) Micro 850 Terminal Strip = 4.4 lb-in
r) 2080 TC2 = 2.21 lb-in
s) 2080 IF4 = 2.21 lb-in
t) 2080 IF2 = 2.21 lb-in
u) HMI = 5 lb-in
v) Yellow Terminal Jumpers = 7.1 lb-in
w) Estop Contact (800F-X01) = 8 lb-in
x) Relay Base Screws (700-HN153) = 7 lb-in
y) IF8 = 5.3 lb-in
z) Relay Output Module = 5.3 lb-in
aa) 10A Circuit Breaker (18 AWG) = 13.3 lb-in
bb) 10A Circuit Breaker (14 AWG) = 17.7 lb-in
cc) 10A Circuit Breaker (8 AWG) = 39.9 lb-in
dd) Ewon Flexy Power Connector = 7 lb-in
ee) Ewon Cosy Power Connector = 7 lb-in
ff) 125V Plug = 12 lb-in