Page 36
The current sensor clamp when installed on the live conductor is positioned with the label “This side
facing main meter” facing towards the utility meter.
If it is more convenient, the sensor can be installed on the neutral supply cable instead of the live. In this
case the label “This side facing main meter” should face away from the utility meter.
Henley
Block
PV System
Isolator
Current Sensor Positioning with Multiple Consumer Units.
Position sensor on utility meter side of “Henley” block
Consumer Unit
Consumer Unit
PV System
Isolator
<<< or >>>
Apollo GEM Installation Manual