Page 12
Error Message Display
If no errors are detected by the system the bottom line of the display will show the current
power being imported to or exported from the property.
If the system detects an error this is displayed on the bottom line of the display instead of the
import/export power.
This is the normal display. No errors are
detected and the display shows how much
power is being imported to or exported from
the property.
Communication with the power sensor
transmitter has been lost. (wireless systems
only) Check the power sensor is on and is
showing a green or orange light. Optimising will
be disabled.
Pairing with a new sensor has been requested
from the set-up menu or at new installation.
See paring later in the manual for more
information.
This message can displayed on the third line of
the display if the temperature control has
been set to "sensor". The unit has detected
that no current is flowing to the heater but the
set temperature has not yet been reached.
Usually due to the heater thermostat being set
lower that the temperature set in the menu,
but could indicate a faulty thermostat or
heater.
[ Check Heater ]
[Pairing New Sensor]