Working Standard
User’s Guide
WS-UGFW619-EN www.appliedp.com
92
Request for measured samples of the waveform. Returns first 64 values from specific channel (phase
(0=L1, 1=L2, 2=L3), unit (0=U, 1=I)). Answer: amplitude samples (64 comma separated real
numbers).
MEAS:SIGN:AMPL? {<phase (0|1|2)>},{< unit (0|1)>}
Request for measured amplitude values of higher harmonic content. Returns first 40 values from
specific channel (phase (0=L1, 1=L2, 2=L3), unit (0=U, 1=I)). Answer: 40 comma separated real
numbers.
MEAS:SIGN:PHAS? {<phase (0|1|2)>},{< unit (0|1)>}
Request for measured phase shifts of higher harmonic content. Returns first 40 values from specific
channel (phase (0=L1, 1=L2, 2=L3), unit (0=U, 1=I). Answer: phase shifts (40 comma separated
numbers).
MEAS:OPER {<param>}
Setting of Operation Mode. Parameter is Operation Mode’s number (0-7) or code (P6-K3).
MEAS:OPER?
Request for setting of Operation Mode. Replay is Operation Mode’s number (0-7).
MEAS:CONN:TYP {<param>}
Connection setting. Parameters: 0 - 3P4W, 1 - 3P3W, 2 - 2P3W, 3 - 1P3W, 4 - 1P2W
MEAS:CONN:TYP?
Request for connection setting. Answers: 0 - 3P4W, 1 - 3P3W, 2 - 2P3W, 3 - 1P3W, 4 - 1P2W
MEAS:CHNLA:AC?
Request for values from Input A.
MEAS:CHNLA:AC:PHAS?
Request for values of phases from Input A.
MEAS:CHNLA:AC:SUM:SQ?
Request for sum of square voltages or currents from Input A.
MEAS:CHNLA:AC:DIST?
Request for distortion of measured voltage or current from Input A.
MEAS:CHNLA:MOD?
Request for accessories type connected to Input A.
Answer can be: 2 … voltage, 1 … current, 0 … none.
MEAS:CHNLB:AC?
Request for values from Input B.
MEAS:CHNLB:AC:PHAS?
Request for values of phases from Input B.
MEAS:CHNLB:AC:SUM:SQ?
Request for sum of square voltages or currents from Input B.
MEAS:CHNLB:AC:DIST?
Request for the distortion of measured voltage or current from Input B.

Other manuals for Applied Precision WS 2120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Applied Precision WS 2120 and is the answer not in the manual?

Applied Precision WS 2120 Specifications

General IconGeneral
BrandApplied Precision
ModelWS 2120
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals