EasyManua.ls Logo

Aqua HC151+ MULTI - Security > Level Input Polarity; Security > Low Level Delay

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HC151+
MULTI / HC200+
MULTI
ENGLISH
3.9.3 Security > Level Input Polarity
It is possible to invert the polarity of the level probe connected to the pump from Normally Open (N.O.)
to Normally Closed (N.C.) and vice versa.
Here are the steps to set up this feature:
3.9.4 Security > Low Level Delay
With this function it is possible to delay the stop of the pump (and of the dosage) following the activation of the
tank level sensor.
When this function is active, and the level of the chemical reaches the minimum, the level alarm is activated
on the pump (on display, in the lower right corner, the text * LVL * will appear) but the pump continues to dose
for the time set, after which it stops.
When using a suction lance that maintains a safety margin, activating the level (without stopping the dosage)
allows you to have time to set up a new tank, without stop the pump dosing. This ensures better continuity of
dosage.
ATTENTION: this function must be activated only if you are using the suction lance with safety margin
like the LAFL of AQUA SPA (see photo below).
It is possible to set
a delay in minutes
according to the
size of the tank in
use and the
quantity dosed by
the pump, to help
the installer, a table
with the settable
times is presented
at the bottom of this
manual.
Next are the steps to set up this
function

Related product manuals