Dual exposed shower with fixed and adjustable shower heads installation instuctions page 13
Trouble shooting guide
Water output is either all
hot or all cold, or cold only.
Symptom Possible cause Action
Reversed inlet supplies Check that the supplies
correspond with the inlet
markings
Water output is not hot
enough
The temperature of the hot
water cylinder is too low
Water flow through the
appliance is too fast
Water flow through the hot
water appliance is too fast
The cylinder temperature
should be at least 15˚c
hotter than the blend
Check the flow rate
recommendations with the
heater manufacturer
Adjust the flow control
knob on the mixer valve
to reduce flow until a
comfortable showering
temperature is achieved
Flow rate is poor and water
temperature is low
Airlock in the water supply Check that the pipe work is
laid in accordance with the
correct practices, paying
particular attention to
potential air-traps
Water temperature
regularly swings between
hot and cold
Cold water pressure is too
high
If the static water pressure
exceeds 10 bar, install
pressure reducing valve
(PRV) in accordance with
the installation guide
Poor flow rate Twisted hose
Debris in shower head
Debris in filters
Check and clear as
necessary