72
ITGB
MENU RANGE NOTES
2
Boiler
param-
eters
24 Heating - 2
240 Minimum pressure 0.3 ÷ 0.4 bar
241 Alert pressure 0.4 ÷ 0.8 bar
242 Filling pressure 0.9 ÷ 1.5 bar
243 Heating post-ventilation
0 : Disabled
1 : Enabled
244 Increase time 0 ÷ 60 min
247 CH Press Detection Device
0 : T Probes Only
1 :
Pressure Switch
2 : Pressure Sensor
248 Enable lling
0 : Disabled
1 : Enabled
25 Domestic hot water
250 Comfort Function
0 : Disabled
1 : Scheduled
2 : Always enabled
251 Comfort Anti-cycling Time 1 ÷ 120 min
252 DHW Start Delay 0.5 ÷ 20 sec
253 DHW Switch O Logic
0 : Anti-limescale
1 : 4ºC Over Setpoint
254 DHW Post Cooling
0 : Disabled
1 : Enabled
255 Delay DHW->CH 0 ÷ 30 min
29 Reset settings 290 Reset Factory Setting
0 : No
1 : Yes
menu summary table