63
ITGB
assistance parameters
Press the Menu button.
Turn the knob and select menu 8 Assis-
tance Parameters; press the con rma-
tion button. Turn the knob and select the
parameter 81 Access code, then press the
con rmation button. Turn the knob to enter
the access code and press the con rmation
button.
Turn the knob and select:
- 82 Boiler
press the con rmation button and turn the
knob to select one of the following options:
820 Burner modulation level
821 Fan status
822 Fan speed
823 Pump speed level
824 Diverter valve position
825 Domestic hot water output  ow
826 Flue gas pressure switch status
Press the con rmation button and turn the
knob to change the value (for the  rst three
parameters), then press the con rmation
button. Press the exit button to return to the
previous screen.
- 83 Boiler T
press the con rmation button and turn the
knob to select one of the following options:
830 set heating T
831 heating ow T
832 heating return T
833 recorded domestic hot water T
834  ue gas T
Press the con rmation button and turn the
knob to change the value (for the  rst three
parameters), then press the con rmation
button. Press the exit button to return to the
previous screen.