EasyManua.ls Logo

Ariston CLIMA MANAGER - Page 75

Ariston CLIMA MANAGER
220 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
ITGB
MENU RANGE NOTES
5
Zone 2 Pa-
rameters
50 Set temperatures
500 Daytime T 10 ÷ 30 °C
501 Night-time T 10 ÷ 30 °C
502 Fixed heating T 20 ÷ 85 °C
51 Access code
52 Zone 2 settings
520 System temperature range
0 : Low temperature
1 : High temperature
521 Temperature adjustment
0 : Fixed  ow temperature
1 : On/o devices
2 : Room sensor only
3 : Outdoor sensor only
4 :Room sensor + Outdoor sensor
522 Slop 0,2 ÷ 3,5
523 O set 1 ÷ 20
524 Room in uence 0 ÷ 20
525 Max. Temperature 40 ÷ 85 °C
526 Min. Temperature 20 ÷ 82 °C
53 Zone 2 diagnostics
530 Room Temperature
read-only531 Flow Temperature
532 Return Temperature
533 Set Temperature
milti-zone
module
534 Request status
535 Pump status
55 Multi-zone
550 Hydraulic Compensator Temp.
milti-zone
module
551 Flow Temp. O set
menu summary table