REMOTE CONTROL DEVICE TECHNICAL DATA
Power supply BUS
Electrical absorption max. < 0.5W
Operating temperature -10 to 60°C
Storage temperature -20 to 70°C
Bus wire length and cross-sectional area
NOTE: IN ORDER TO AVOID INTERFERENCE
PROBLEMS, USE
A SHIELDED CABLE OR
TWISTED PAIR CABLE.
max. 50 m
min. 0.5 mm²
Buffer memory 2 h
Conformity
LVD 2006/95/EC - EMC 2004/108/EC
Electromagnetic interference EN 60730-1
Electromagnetic emissions EN 60730-1
Conformity to standards EN 60730-1
Temperature sensor NTC 5 k 1%
Resolution degree 0.1°C
134 mm 16 mm
96 mm
REMOTE CONTROL DEVICES OUTDOOR SENSOR
Position the outdoor sensor on the north-facing wall of the building,
at least 2.5 m from the ground and away from direct sunlight.
Remove the cover (fi g. A) and install the sensor using the rawl plug
and screw provided (fi g. B).
Make the connection using a 2x0.5 mm
2
cable.
Maximum connection length 50 m.
Connect the wire to the terminal (fi g. C) by introducing it from the
lower part after creating a suitable passage.
Place the sensor cover back in the correct position.
AB C
PRODUCT FICHE
SUPPLIER’S NAME ARISTON
SUPPLIER’S MODEL IDENTIFIER SENSYS OUTDOOR SENSOR
Class of the temperature control V II
Contribution to seasonal space heating energy effi ciency in % +3% +2%
Adding an Ariston Outdoor Sensor:
Class of the temperature control VI --
Contribution to seasonal space heating energy effi ciency in % +4% --
In a 3-zones system with 2 Ariston Room Sensors
Class of the temperature control VIII --
Contribution to seasonal space heating energy effi ciency in % +5% --