86 /
MENU
SUB-MENU
PARAMETER
DESCRIPTION RANGE FACTORY SETTINGS
12 6 7 Force Hp Cool OFF - ON OFF
12 6 8 Force WHB OFF - ON OFF
12 6 9 Anode output OFF - ON OFF
12 7 Manual Mode - 2
12 7 0 Manual mode activation
OFF - ON OFF
12 7 1 Rating Heating Mode
OFF - ON OFF
12 7 2 Rating Cooling Mode
OFF - ON OFF
12 7 3 Compressor frequency setting
18 ÷ 120 Hz 120 Hz
12 7 4 Fan 1 rpm setting
0 ÷ 1000 rpm 500 rpm
12 7 5 Fan 2 rpm setting
0 ÷ 1000 rpm 500 rpm
12 7 7 Ext Unit Electric Heater Activation OFF - ON OFF
12 8 Test & Utilities
12 8 0 Air-purge function OFF - ON OFF
12 8 1 Floor drying cycle
OFF
Functional Heating
Curing Heating
Functional Heating + Curing Heating
Curing Heating + Functional Heating
Manual
OFF
12 8 2 Floor drying total Remaining Days only reading
12 8 3 Floor drying funct. Remaining Days only reading
12 8 4 Floor drying curing Remaining Days only reading
12 8 6 Defrost OFF - ON only reading
12 9 Impostazione tari e energetiche
12 9 0 Min Rapporto Costo Elettricità/Gas 0,5 - 4 0,5
12 9 1 Max Rapporto Costo Elettricità/Gas 0,5 - 4 4
12 9 2 Rapp.Energ. Primar./Elettric. (Valx100) 150 - 350 200
12 9 3 Costo kWh gas (PCS) 1 - 50 Euro, cent. 5 Euro, cent.
12 9 4 Costo kWh elettricità 1 - 50 Euro, cent. 11 Euro, cent.
12 9 5 Costo kWh elettricità tari a ridotta 1 - 50 Euro, cent. 7,8 Euro, cent.
12 9 6 External Boiler E ciency CH 0 - 100% 90%
12 9 7 External Boiler E ciency DHW 0 - 100% 90%
12 9 8 Delta T COP Setpoint 0 - 20°C 5°C
12 10 Energy Manager Statistics only reading
12 10 0 HP Heating Running hours (h/10) only reading
12 10 1 HP+Boil ON running hours (h/10) only reading
12 10 2 HP On cycles (n/10) only reading
12 10 3 HP Defrost hours (h/10) only reading
12 10 4 Cooling running hours (h/10) only reading
12 10 5 Heating running hours (h/10) only reading
12 10 6 DHW running hours (h/10) only reading
12 11 Energy Manager Info only reading
12 11 0 kWh cost from HP Actual only reading (Euro, cent.)
12 11 1 kWh cost from Boiler Actual only reading (Euro, cent.)
12 11 2 kWh cost from HP Estimated only reading (Euro, cent.)
12 11 3 kWh cost from Boiler Estimated
only readinga (Euro,
cent.)
12 12 HP Diagnostics - 1
12 12 0 Outside air temperature only reading (°C)

Other manuals for Ariston NIMBUS HYBRID MODULE UNIVERSAL NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston NIMBUS HYBRID MODULE UNIVERSAL NET and is the answer not in the manual?

Ariston NIMBUS HYBRID MODULE UNIVERSAL NET Specifications

General IconGeneral
BrandAriston
ModelNIMBUS HYBRID MODULE UNIVERSAL NET
CategoryControl Unit
LanguageEnglish

Related product manuals