© 2023 Carrier 1 / 16 P/N PAK200953-ML • REV F • ISS 12JAN23
AS280G3 Internal Siren Installation Sheet
EN
FR
NL
2
4
5
EN: Installation Sheet
Operation
AS280G3 Internal Siren is used for notification of an alarm
condition as generated within an intruder, hold-up or other
alarm system. In response to commands from the alarm
system control panel, the AS280G3 will emit a high intensity
sound.
AS280G3 will detect any attempt to gain unauthorised access
to the sounder by removal of the cover, or any attempt to
remove it away from its mounting surface. This will generate a
Tamper (Auto-protection) signal which is normally fed back to
the alarm control panel. Integrity of the Trigger Command
(1)
(2)(1)
(3) (3)
(3) (3)
(5)
(4)
(6)
(11) CP
4K7
(5)
(7) TMP
+
(3) AUX+
(4) 0V
(6) TMP IN
(9) Alarm
(10) PROG OUT
(10) PROG OUT
(8) FLT IN
(8) FLT IN
BAT+
BAT
ALIM+
ALIM
AP(S)
AP(R)
FAUTE
FAUTE
BL+
ING
TEST
AS280G3
(1)
(2)
(13) AS280G3 (EOL)(12) AS280G3
ALIM+
ALIM
AP(S)
AP(R)
FAUTE
FAUTE
BL+
ING
TEST
ALIM+
ALIM
AP(S)
AP(R)
FAUTE
FAUTE
BL+
ING
TEST
(11) CP
4K7
(5)
(3) AUX+
(4) 0V
(6) TMP IN
(9) Alarm
(10) PROG OUT
(8) FLT IN
(8) FLT IN
(10) PROG OUT
(7) TMP
(11) ATSx500A
(7) TMP
+
(3) AUX+
(4) 0V
(6) SIR TMP
(9) SIR. S1
(10) OUTPUT n
(10) OUTPUT n
(8) INPUT n
(8) INPUT C
BAT+
BAT
ALIM+
ALIM
AP(S)
AP(R)
FAUTE
FAUTE
BL+
ING
TEST
AS280G3
(1)
(2)
4K7
4K7
4K7
1K
Question and Answer IconNeed help?

Do you have a question about the Aritech AS280G3 and is the answer not in the manual?

Aritech AS280G3 Specifications

General IconGeneral
TypeControl Panel
Zones8
CommunicationPSTN, GSM
Input Voltage230 VAC
Battery Backup7 Ah

Summary

Installation Sheet Operation

Siren Operation Details

Explains the AS280G3's function for alarm notification and high-intensity sound emission.

Engineer Mode

Engineer Mode Functionality

Enables silent start-up and maintenance by connecting the ENG input to a programmable control panel output.

Self-Test and Fault Output

Automatic Self-Testing

Details the AS280G3's 24-hour self-test for battery integrity and the resulting Fault output.

Remote Test Functionality

Initiating a Remote Self-Test

Describes how to force a self-test by applying a high signal to the Remote Test/TEST input.

Tamper Circuitry and SAD Mode

Tamper Circuit for Cascade Installations

Explains the auto-protection circuit for single and multiple cascade siren installations.

SAD Mode Configuration

Defines the sounder's response to tamper conditions when SAD mode is selected.

Connections and Installation

Terminal Descriptions

Details each terminal function (e.g., BAT+, ALIM+, ING, TEST) for correct wiring.

Mounting and Fixing Procedures

Instructions for physically installing the siren housing, backplate, and securing it to a surface.

Commissioning and Maintenance

Commissioning Steps

Procedure for setting links, connecting wires, and performing initial functional tests.

Periodic Maintenance Checks

Regular checks for sounder operation from the control panel and tamper functionality.

Battery Removal and Replacement

Guidelines for safely removing and installing the internal battery, ensuring correct polarity.

Diagnostic Information

Diagnostic Tones and Meanings

Explanation of diagnostic tones indicating status like tamper closing, opening, or battery faults.

Diagnostic LED Indicators

Details on LED flashes and their meaning for battery status, test failures, or charger issues.

Troubleshooting and Specifications

Troubleshooting Common Faults

Guide to identifying and resolving issues like unexpected sounder activation or panel setting problems.

Technical Specifications

Details on sound output, power supply, current consumption, cut-off timer, and battery.

End of Life Product Disposal

Information on proper disposal of the product and battery according to WEEE and battery directives.

Related product manuals