EasyManua.ls Logo

Armstrong Air Conditioning A96DS2V User Manual

Armstrong Air Conditioning A96DS2V
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
507405-05 Page 1 of 72Issue 1621
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
CAUTION
Manufactured By
Allied Air Enterprises LLC
A Lennox International, Inc. Company
215 Metropolitan Drive
West Columbia, SC 29170
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
WARNING
(P) 507405-05
*P507405-05*
This manual must be left with the homeowner for future reference.
INSTALLATION INSTRUCTIONS
A96DS2V
Warm Air Gas Furnace / Downow Air Discharge
Direct Vent & Non-Direct Vent
TABLE OF CONTENTS
Unit Dimensions ................................................................ 2
Parts Arrangement............................................................. 3
Gas Furnace ...................................................................... 4
Shipping and Packing List ................................................. 4
Safety Information ............................................................. 4
Use of Furnace as Construction Heater ............................ 5
General .............................................................................. 6
Combustion, Dilution & Ventilation Air ............................... 6
Setting Equipment ............................................................. 9
Filters ............................................................................... 12
Duct System .................................................................... 12
Pipe & Fittings Specications .......................................... 12
Joint Cementing Procedure ............................................. 14
Venting Practices ............................................................. 14
Vent Piping Guidelines .................................................... 15
Gas Piping ....................................................................... 34
Electrical .......................................................................... 36
Unit Start-Up .................................................................... 52
Gas Pressure Adjustment ................................................ 53
High Altitude Information ................................................. 54
Other Unit Adjustments.................................................... 55
Blower Motor Performance .............................................. 56
Integrated Control Diagnostic Modes .............................. 60
Service............................................................................. 67
Planned Service .............................................................. 69
Start-Up & Performance Check List ................................ 70
Question and Answer IconNeed help?

Do you have a question about the Armstrong Air Conditioning A96DS2V and is the answer not in the manual?

Armstrong Air Conditioning A96DS2V Specifications

General IconGeneral
ModelA96DS2V
CategoryFurnace
TypeGas
Efficiency96% AFUE
Blower MotorVariable Speed
StagesTwo-Stage
IgnitionHot Surface Ignition
WarrantyLimited Lifetime Heat Exchanger, 10-year Parts
Fuel TypeNatural Gas

Summary

Installation Instructions A96DS2V

Safety Information

Provides critical safety warnings regarding installation, adjustment, alteration, service, or maintenance.

Locations and Clearances

Specifies required clearances for furnace installation to combustible materials.

Combustion, Dilution & Ventilation Air

Details requirements for combustion air supply and ventilation, especially for Non-Direct Vent applications.

INSTALLATION – Setting Equipment

Provides instructions on how to properly set the furnace, including leveling and clearances.

Pipe & Fittings Specifications

Lists approved materials for vent piping, fittings, primer, and solvent cement.

Vent Piping Guidelines

Details installation guidelines for vent piping, including direct vent and non-direct vent configurations.

Vent Termination Clearances For Non-Direct Vent Installations

Specifies required clearances for vent terminations in Non-Direct Vent installations.

Vent Termination Clearances For Direct Vent installations

Specifies required clearances for vent terminations in Direct Vent installations.

Gas Piping

Provides guidelines and safety precautions for gas piping installation.

Gas Pressure Adjustment

Details on how to adjust and measure gas pressure for proper furnace operation.

Proper Combustion

Guidance on achieving proper combustion and checking CO2 levels.

Electrical

Electrical safety precautions and checks during installation and servicing.

Integrated Control Diagnostic Modes

Explains how to access and interpret diagnostic codes and statuses from the integrated control.

Program Unit Capacity / Size Mode

Procedure for configuring the furnace's unit capacity/size code for proper operation.

Service

General safety precautions and procedures for servicing the furnace.

Start-Up & Performance Check List

A checklist to guide the start-up and performance verification of the furnace.

UNIT OPERATION HEATING MODE

Parameters to check and record during heating mode operation.

UNIT OPERATION COOLING MODE

Parameters to check and record during cooling mode operation.