72
Low Range
Resolution
Accuracy @I>3A
0.0666~6.66Ω
0.1mΩ
0.5%+40mΩ
0.0666~6.66Ω
0.1mΩ
0.5%+40mΩ
Middle Range
Resolution
Accuracy @V>20V
6.66~666Ω
2.6uS
0.3%+375uS
6.66~666Ω
2.6uS
0.3%+375uS
High Range
Resolution
Accuracy @V>20V
66.6~6660Ω
0.29uS
0.3%+188uS
66.6~6660Ω
0.29uS
0.3%+188uS
Constant Power Mode
Range
Resolution @P<100W
@P100W
Accuracy
0~200W
1mW
10mW
0.2%+600mW
0~350W
1mW
10mW
0.2%+600mW
Current Measurement
Low Range
Resolution
Accuracy
0~2A
0.1mA
0.05%+4mA
0~3A
0.1mA
0.05%+4mA
High Range
Resolution
Accuracy
0~20A
1mA
0.05%+8mA
0~30A
1mA
0.05%+8mA
Voltage Measurement
Range
Resolution
Accuracy
0~200V
1mV
0.1%+50mV
0~200V
1mV
0.1%+50mV
Power Measurement
Range
Resolution @P<100W
@P100W
Accuracy
0~200W
1mW
10mW
0.1%+600mW
0~350W
1mW
10mW
0.1%+600mW
Current Slew Rates
Range CCH
CCL
*3
1mA/us~2A/us
100uA/us~200mA/us
1mA/us~3A/us
100uA/us~300mA/us
Resolution 1mA/us 1mA/us
Accuracy
*4
3% + 10us 3% + 10us
Transient Operation
Transient Mode Continuous, Pulse, Toggled Continuous, Pulse, Toggled

Table of Contents