7.7. Appendix 7: Technical Specifications of AMT Toolkit
GENERAL INFORMATION
Net Weight
18 kg (39 lb)
Device Dimensions (W x H x L)
550x310x190 mm (21.6x12.2x7.5 in)
Mounting
Portable (indoor use)
AMBIENT CONDITIONS
Operating Temperature
0-40°C (32-104 °F)
Humidity
90%, non-condensing
Pollution Degree
2
Altitude
2000 m (6562 ft)
INPUT SUPPLY VOLTAGE
The power supply voltage must be connected to the AMU unit
Via a UL listed fuse
15A
Over voltage category
CAT II
Voltage
100-240VAC 50/60Hz, (Use UL listed 15A fuse