18
asberprofessional.com
7.- Conversion Instructions:
7.1Gas valve conversion:
NOTE: This is aRobertshaw 7000 Series (MV) gas valve (LP) conversion kit
for ASBER Fryer Model AEF-4050.
1. Turn OFF the fryer from the gas
a. supply.
2. Partially depress and turn the gas
knobthe OFF position.
3. Removethefollowingitems:
two screws thru regulator
regulator
gasket
4. Install the new gasket, cover plate and two
screws provided in the conversionkit.
5. Install the NEW PILOT orifice. See PILOT
drawing ON RIGH.
6. Turn on the gas supply and check forleaks
using a solution of soapy water.
7. If there are no leaks, proceed with thenext
step.
8. Turn the gas knob to the Pilot positionand
depress and light the PILOT.
Adjust the gas pressure asnecessary, per
procedures on thereverse of this sheet.
NOTE: USE GASLINE THREAD SEALERON
ALL THREADED CONNECTIONS!