5. TROUBLE SHOOTING
PROBLEM
PROBABLE CAUSE
REMEDY
Pilot will not light
a. No gas
b. Gas tap dial not set at “Pilot”
position and depressed.
a. Turn main gas
valve “ON”
b. Set gas tap dial on
combination gas
valve to “Pilot”.
Depress and hold
while lighting.
Pilot will not stay lit
a. Gas tap dial not depressed and
held long enough
b. Defectivethermopile
c. Pilot flame not properly adjusted
a. Depress and hold
for at least 30 sec.
b. Replace
c. Adjust pilot flame
with pilot
adjustment screw
on the combination
valve.
Main burners will
not ignite
a. Pilotnotlit
b. Thermopile not properly installed
in the pilot.
c. Gas tap dial not set at ON”
position.
d. Thermostat not set at any
temperature.
e. Defective gas valve.
f. Defective hi-limitswitch.
a. Light the pilot
b. Push in ad tightens.
Pilot flame should
engulf the
thermopile.
c. Turn and set gas
tap dial to “ON”
position.
d. Set thermostat to
desired
temperature.
e. Replace
f. Replace.
Fryer does not heat
up fast
a. Insufficient gas.
b. Line clogged
c. Overloadingthefryer.
a. Check gas
pressure.
b. Remove and clean
gas line
c. Cook smaller loads.
Need larger fryer!