Location requirements
If the drying cabinet is to be installed with
a connection to exhaust air ventilation,
this must be available on the premises.
A grounded electrical outlet must be
within 79 in. (2 meters) of the drying
cabinet’s upper section. A 79-in. (2-me-
ter) grounded power cord with a plug is
connected at the top of the drying cabi-
net. If the electrical outlet is not located
as above, the location must be adjusted
so that an extension cord is not neces-
sary.
The electrical outlet shall be easily ac-
cessible after installation of the drying
cabinet. Take this into consideration even
in cases when the drying cabinet is built
into custom cabinetry or similar framing.
For further information, see the section
“Electrical requirements”.
The floor must be able to support the
weight of the cabinet 133 lbs (60 kg).
The floor must be flat with a slope under
the cabinet of no more than 1 in. (2.5
cm).
The drying cabinet is only intended for
installation indoors and at temperatures
above 0°C (32°F).
The drying cabinet may not be located in
environments where pressurized water
is used for cleaning.
Installation dimensions