Do you have a question about the Assa Abloy ACCENTRA 5400LN Series and is the answer not in the manual?
Brand | Assa Abloy |
---|---|
Model | ACCENTRA 5400LN Series |
Category | Door locks |
Language | English |
Accuracy of door preparation is critical for lock function and security. Misalignment causes premature wear.
Cylindrical locks and latches must be through bolted in all doors for proper installation.
Product may expose to lead, known to cause cancer and reproductive harm. See P65warnings.ca.gov.
Retrofit/modification of fire-rated openings may impact rating. Consult code specialist.
Drill 2-1/8" (54mm) dia. hole (A) and 1" (26mm) dia. hole (B) as per instructions.
Drill two (2) 5/16" (8mm) dia. holes (C) and pilot holes (D) for screws.
Insert latch ensuring bevel faces strike plate. Attach with two screws supplied.
Remove screws, slide rose away, adjust rose plate to door thickness, reassemble.
Insert lockbody ensuring frame hooks latch case and retractor engages bolt tail. Do not force.
Slide inside rose assembly onto lock body, aligning groove with drive lug on spindle.
Place rose scalp on rose assembly. Snap in lever handle, pull to ensure proper seating.
Mark horizontal line on frame, measure half door thickness, drill 1" hole and 1/2" deep.
Align strike holes with vertical line, trace outline, mortise 1/16" deep, attach with screws.
Cycle lock. If it binds when closed, check door and frame alignment. See Troubleshooting.
Verify 1/8" gap between latch and strike. Check hinges for looseness or wear.
Check strike alignment or shim strike if latchbolt won't deadlock.
Verify latchbolt tail and retractor positioning. Adjust rose plate or rebore holes if needed.
Insert key, rotate 70°, depress retainer with tool, slide lever off.
Remove retainer spring pad, slide cylinder out of handle. Ensure spacer is on plug during reassembly.
Secure Rose Support assembly to door with screws/washers, install rose scalp and inside lever.
Remove set screw, slide handle off. Do not overtighten set screw when assembling.
Specific functions (5428LN, 5429LN, 5439LN) allow door thickness adjustment.
Use a soft, damp cloth for cleaning. Avoid lacquer thinners, caustic soaps, or abrasive cleaners.
Use template for square or beveled edge doors. Ensure 1:1 scale printing for accuracy.