EasyManua.ls Logo

Assa Abloy Norton 6000 Series - Turn Off Power; Disconnect and Assemble Arm and Closer; Disconnect Arm From Track (6010;6050 Units); Remove Arm Screw From Pinion

Assa Abloy Norton 6000 Series
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9360-1020-020 Rev 1 02/17
For 6010/6050 Units Only: Disconnect Arm From Track
2a
A. Use small flat blade screw driver to pull clip on
back side of Slide Assembly out to disengage
Arm Stud.
B. Pull up on arm until Arm Stud disengages from
Slide Assembly. CAUTION: Arm will try to close
due to spring power on closer.
Slide
Assembly
Arm Stud
A
B
Remove Arm Screw From Pinion
2b
A. Use 7/16” wrench to
loosen and remove
arm screw and washer.
Disassemble Arm From Pinion
2c
A. Use adjustable wrench to rotate pinion
square on top side of unit approximately 45°
so arm moves away from frame.
B. Remove arm from pinion.
C. Allow adjustable wrench to rotate back and
remove.
Turn off Power
1
A. Turn On/Off switch on end cap to the Off position before proceeding.
Page 2
Disassembe Closer Sub-Assembly
2d
A. Disconnect wiring harnesses from Closer Sub-
Assembly to Back Plate Assembly.
B. Loosen 4 screws holding the Closer Sub-Assembly.
C. Slide Closer Sub-Assembly to side and slide key hole
in back plate over screws to remove Sub-Assembly.
From Closer
Sub-Assembly
From Back
Plate Assembly

Other manuals for Assa Abloy Norton 6000 Series