EasyManua.ls Logo

Astralpool 78550 - 6.3 Cable specification

Astralpool 78550
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.APPENDIX
28
6.3 Cable specification
1. Single phase unit
Nameplate
maximum
current
Phase line Earth line
MCB
Creepage protector Signal line
No more
than 13A
2
1.5mm
2
1.5mm
2
20A
30mA less than 0.1 sec
n
0.5mm
2
13~25A
2
4mm
2
4mm
2
40A
30mA less than 0.1 sec
25~30A
2
6mm
2
6mm
2
40A 30mA less than 0.1 sec
30~40A
2
10mm
2
10
mm
2
63A 30mA less than 0.1 sec
40~55A
2
16mm
2
16
mm
2
80A
30mA less than 0.1 sec
55~70A
2
25mm
2
25
mm
2
100A
30mA less than 0.1 sec
2. Three phase unit
Nameplate
maximum
current
Phase line Neutral line Earth line
MCB
Creepage protector Signal line
No more
than 13A
3 1.5mm
2
1.5mm
2
1.5mm
2
20A
30mA less than 0.1 sec
n
0.5mm
2
13~25A
3
4mm
2
4mm
2
4mm
2
40A 30mA less than 0.1 sec
25~30A
3
6mm
2
4mm
2
6mm
2
40A
30mA less than 0.1 sec
30~40A
3
10mm
2
4mm
2
10mm
2
63A
30mA less than 0.1 sec
40~55A
3
16mm
2
4mm
2
16mm
2
80A
30mA less than 0.1 sec
55~70A
3
25mm
2
4mm
2
25mm
2
100A
30mA less than 0.1 sec
When the unit will be installed at outdoor, please use the cable which can against UV.

Related product manuals