Page 18 Draft Rev. AX5
AdvanTag 9100 Technical Manual
Chapter 2: Theory of Operation
Data Storage—AdvanTag Reader
a
CID_DISPLAY ON = Enable
OFF= Disable
CID_NP_ASCII ON = Enable
OFF= Disable
CID_ERROR ON = Enable
OFF= Disable
CID_JUSTIFY R = Right
L= Left
CID_PAD NUL = 0x00
ZERO = 0x30
Configuration
(Applicable only to version 21A
and later)
01 through 31
ENABLE_EVENTS Enable Events (Pod or Operator
arrival/removal, and powerup.
ON = Event will be generated.
OFF = Events will not be generated.
Default = ON
EXTENDEDSSACK
(Applicable only to version 20C
and later)
Enables the extended error codes in SSACK.
The SEMI standard specifies only five codes
(NO, EE, CE, HE, and TE). When this option
is ON, up to 100 error codes might be
generated. Please see SSACK for all error
code.
ON = All error codes generated.
OFF= Only SEMI standard error codes
generated
HardwareRevisionLevel
Applicable only to version 21A
and later
Subsystem Hardware Rev. of Upstream
Controller OR Head (as applicable)
Up to 8 bytes
HeadID
(Applicable only to version 21A
and later)
Returns the HeadID or TargetID
Two digits
HeadStatus
(Applicable only to version 21A
and later)
IDLE or MANT
HSMS_IP
(SECS only)
HSMS IP address (Passive Connection)
HSMS_PORT
(SECS only)
HSMS Port address (Passive Connection)
HWREV Same as HardwareRevisionLevel
TABLE 3 Attribute Values (ECID and SVID)
Attribute Description and Limits or Values