EasyManua.ls Logo

AT-OS AF2 - Alarm Codes E32-E66

AT-OS AF2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT
OS S.r.l.
Viale del Lavoro, 19 37030 Colognola ai Colli (Verona) Italy
Tel. ++39 045 6159411- Fax ++39 045 6159422 - e-mail: info@at-os.com – www.at-os.com
44
Alarm Malfunction
What to do
Alarm
E32: St.G. Heat: Tout
Displayed if water in the steam generator does not reach a pre-disinfecting
temperature with the preset time interval.
Alarm
E33: Tank Temp. Tout
(OPTIONAL) Displayed after a preset time period if the water in the storage
tank does not reach the preset temperature.
Alarm
E40: StGen Overheated
Warns the user when the steam generator overheats. A Technician must be
called in order to restore correct machine operation.
Alarm
E41: Leak Perist.Pump
Displayed to warn that liquid leakage from a dosing pump has been detected.
Alarm
E42: Clogged Siphon
Displayed to warn the user that the drain trap is clogged and consequently that
the machine cannot function properly until the problem is solved.
Alarm
E43: Door open
This appears when during a washing cicle the door is opened due to technical
or electrical reason.
Alarm
E44: Maintenance
This appears after a certain set number of cicles to indicate that the machine
requires a scheduled maintenance service check
Alarm
E50: Mos Det. Pump
Displayed when there is an electrical problem with the detergent pump.
Alarm
E51: Mos Solvent Pump
Displayed when there is an electrical problem with the solvent pump.
Alarm
E52: Mos SoftenerPump
Displayed when there is an electrical problem with the anti-scale pump.
Alarm
E53: Mos cycle Start
Displayed when there is an electrical problem with the "cycle start" safety
command that gives consent for the heating coil to operate.
Alarm
E54: Mos Sol.Valve 1
Displayed when there is an electrical problem with solenoid valve number "1".
Alarm
E55: Mos Sol.Valve 2
Displayed when there is an electrical problem with solenoid valve number "2".
Alarm
E56: Mos Sol.Valve 3
Displayed when there is an electrical problem with solenoid valve number "3".
Alarm
E57: Mos Sol.Valve 4
Displayed when there is an electrical problem with solenoid valve number "4".
Alarm
E60: Mos Sol.Valve 5
Displayed when there is an electrical problem with solenoid valve number "5".
Alarm
E61: Mos Sol.Valve 6
Displayed when there is an electrical problem with solenoid valve number "6".
Alarm
E62: Mos Sol.Valve 7
Displayed when there is an electrical problem with solenoid valve number "7".
Alarm
E63: Mos Sol.Valve 8
Displayed when there is an electrical problem with solenoid valve number "8".
Alarm
E64: Mos Fan 1
Displayed when there is an electrical problem with cooling fan n. 1.
Alarm
E65: Mos Fan 2
Displayed when there is an electrical problem with cooling fan n. 2.
Alarm
E66: Mos Door
Displayed when there is an electrical problem with the automatic door jack
(only on models AF2.60Ex).