Viale del Lavoro, 19 37030 Colognola ai Colli (Verona) Italy
Tel. ++39 045 6159411- Fax ++39 045 6159422 - e-mail: info@at-os.com – www.at-os.com
43
11.5 Alarm messages
The machine is programmed to give alarm messages when it is operating.
Here is an example of two lines of alarm message on the display (see paragraph 11.2.1 “Display”)
In the following table the "Alarm" column indicates the message that appears on the first and second line of the machine's display
and the "Malfunction" column gives the cause that generated the message:
Alarm Malfunction
What to do
Alarm
E00: PTC Probe Break
Displayed if a supply cable for a temperature probe (PTC) in the wash basin is
cut off.
Alarm
E01: PTC Probe Short C
Displayed if a temperature probe (PTC) in the wash basin is shorted.
Alarm
E02: No PTC Connected
Displayed if no temperature probe (PTC) as enabled to operate.
Alarm
E03: Plumb.Syst.Probl
Displayed when there are plumbing problems (solenoid valves and/or tubes
clogged or pump broken) that prevent water from exiting from the storage tank.
Alarm
E04: Detergent Empty
Displayed when detergent is finished (the empty drum must be replaced with a
drum filled with the same liquid).
Alarm
E05: Solvent Empty
Displayed when solvent is finished (the empty drum must be replaced with a
drum filled with the same liquid).
Alarm
E10: Water not Filled
Displayed when the water level in the storage tank is not reached within a
preset time period.
Alarm
E11: Low W. Lev. Off
Displayed when there are operating problems with the level probes installed in
the water storage tank (broken, disconnected or dirty).
Alarm
E12: Door timeout
Displayed when there are problems opening/closing the door that cause a
substantial delay in performance of this procedure.
Alarm
E13: Door overloading
Displayed when the stress performed by the door open/close motor is greater
than the safety level: generally caused by objects that prevent the door from
opening/closing.
Alarm
E14: Door Sensor ERR.
Displayed when there are problems with the magnetic door closed sensor
which is either disconnected or damaged.
Alarm
E15: Manual Interrup.
Displayed when the "Reset" key is pressed while the machine is in stand-by or
when the door is opening/closing.
Alarm
E20: NO Disinfection
Displayed if the machine is not able to maintain the disinfecting temperature for
the preset time period and consequently disinfecting has not taken place.
Alarm
E21: SteamGen Timeout
Displayed when the maximum time period necessary to load water into the
steam generator is exceeded.
Alarm
E22: Sol. Valves Off
Displayed at the start of a cycle wash phase when none of the solenoid valves
has been programmed to open.
Alarm
E30: Softener Empty
Displayed when the anti-scale product is finished (the empty tank must be
replaced by a tank filled with the same liquid).
Alarm
E31: Temp Not Reached
Displayed if the disinfecting temperature in the wash chamber is not reached in
the preset time interval.