12 MAINTENANCE
It is good practice, especially when there is very hard water in the water mains, to perform
inspection and cleaning procedures at periodic intervals.
Be very careful with the heating coils (the element that heats the steam g
enerator) and the
level probes
12.1.1 Safety thermostat
The machine is equipped with a safety thermostat (only machine models with steam generators, meaning with self-generated steam)
that interrupts power to the steam generator heating coils when the temperature of the heating coils exceeds a certain limit.
Exceeding this limit could cause damage to the heating elements. To restart the appliance you must eliminate the causes (the
display will show the error message: "E40: Overheating", refer to paragraph 11.5 regarding alarm messages).
12.2 Weekly checks
12.2.1 Anti-scale product
Periodically check the level of anti-scale product contained in the drum (when present) located in the compartment below the wash
basin. A label near the cap indicates the type of liquid contained in the drum (see picture I on page IV appendix I). A message on the
display warns when the liquid is getting low and when it is totally finished (see paragraph 11.5 regarding alarm messages). For more
information regarding the anti-scale product consult chapter 9 of this manual.
Recommended product: "SBN" or "AT-OS Decalcenex"
12.2.2 Detergent
Periodically check the level of detergent liquid contained in the drum (when present) located in the compartment below the wash
basin. A label near the cap indicates the type of liquid contained in the drum (see picture I on page IV appendix I). A message on the
display warns when the liquid is getting low and when it is totally finished (see paragraph 11.5 regarding alarm messages). For more
information regarding the detergent liquid consult chapter 9 of this manual.
Recommended product: "SBR" or "AT-OS Clear"
Use only products recommended by AT
-
OS S.r.l. because these have already been tested
on the machine. If the machine has two drums be careful not to mix up the aspiration
nozzles when the empty drums are replaced. Always read the colored label near the drum
cap and the label on the drum of liquid.