GB-23
Parameter synoptic
Entry into the time program level: Hold rotary push-button depressed for 3 seconds - automatic call-up of time program level
Select required level with rotary pushbutton and confirm, if necessary enter code beforehand
Without colour: Directly accessible
Light gray background: accessible with code 1234
Dark gray background: accessible with code 0123
Programming Configuration Parameter settings (heating circuits, control intervals)
Parame
ter no.
Time-
Date
Time
pro-
grams
Hydrau-
lic
System
para-
meters
Domes-
tic hot
water
Unmixed
circ.
(..2..)
Mixed
circ. 1
(..3..)
Mixed
circ. 2
(..33..)
Heating
unit
(..2..)
1
TIME
(min/h)
Heat. selection
HC,MC1/2,
DHW
Installation
diagram
Language
DHW economy
temperature
Reduced
operation
Reduced
operation
Reduced
operation
Type
2 Year
Select program
P1...P3
Domestic hot
water
supply
Time
programs
Legionella
protection
(week-day)
Exponent
heating curve
Heating
system
Heating
system
3
Day-
month
Week-day
Mo...Su
Heat. cycle
(1...3)
Function MC1
Enabling
separated mode
Legionella
protection
(time)
Room sensor
display
Room sensor Room sensor
Minimum
temperature
4
Su-Wi-
timer
Switching-on
time
Function MC 2
Temperature
ECO
Legionella
protection
(temperature)
Room sensor
function
Room sensor
function
Room sensor
function
Maximum
temperature
5 Switch-off time Function HC
System frost
protection
Signal source
Heating curve
adaptation
Heating curve
adaptation
Heating curve
adaptation
6
Room / dhw
temperature
Function VO1
Heat demand
VI-1
DHW-
maximum limit
Inrush
optimization
Inrush
optimization
Inrush
optimization
7 Function VO 2
Heat demand
VI-2
DHW
programs
8 Function VI -1
Heat demand
VI-3
Cool down
protection
Room frost
protection
temperat ure
Room frost
protection
temperat ure
Room frost
protection
temperat ure
9 Function VI 2 Climate zone DHW-Tset
Exceeding
room
temperature
Exceeding
room
temperature
Exceeding
room
temperature
10 Function VI 3
Type of
building
DHW-
switching
difference
Allocation
outside sensor
Allocation
outside sensor
Allocation
outside sensor
11
minimum
boiler return flow
temperature
Back to
standard
display
DHW-charge
pump
Constant
control
Constant
control
Constant
control
12 Forced control
Program charge
pump
Minimum flow
temperature
Minimum flow
temperature
Minimum flow
temperature
13
Logical error
messages
Economy interval
charge pump
Maximum flow
temperature
Maximum flow
temperature
Maximum flow
temperature
14 Auto SET Cycle AUP Temp. rise Tset Temp. rise Tset Temp. rise Tset
15
Reset to
factory values
Pump after-run
(HCP)
Pump after-run
(MC1-P)
Pump after-run
(MC2-P)
16
DHW basic
temperature
Screed
function
Screed
function
Screed
function
17
Maximum
return flow
temperature
Maximum
return flow
temperature
18
19
20
21
22
23
24
25
Set
temperature
day
Set
temperature
day
Set
temperature
day
26
Set
temperature
night
Set
temperature
night
Set
temperature
night
27
Heating curve
slope
Heating curve
slope
Heating curve
slope
28