AT&T Private Pay Phone Plus February, 1988
The mounting area for the post must be a level and structurally sound surface. A vertical
phone mounting surface is needed to insure that the coin chute within the phone functions
properly.
Once a structurally-sound surface has been determined, you must obtain the fasteners
(anchors) necessary to mount the post. Eight anchors are required at the base (4 on each
side) of the post for mounting purposes. Refer to Figure 15. Setscrews (Item 10) provide
leveling jacks to assure a vertical phone mounting.
Before the post can be mounted a power cable, 2-conductor telephone line cord, and
ground wire must be laid. Entrance holes for the pow er cable, telephone line cord, and
ground wire are provided at the top and bottom of the post for overhead or underground
entrance. An aluminum panel on the front of the post provides access to an electrical outlet
box and protector for terminating the power and telephone service coming to the post, and
for mounting an optional light control and circuit-breaker. Refer to Figures 1 5 and 16.
Owner Manual
Page 39