EasyManua.ls Logo

Atlas Copco CD 1+ - Controller Specifications

Atlas Copco CD 1+
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Timing cycle
Controller specifications
Ambient temperature: 1.5 °C to 50 °C (35 °F to 122 °F)
Maximum relative humidity (RH): 80% for temperatures up to 31 °C, decreasing linearly to 50% at
50 °C
Input voltage: 110 or 230 VAC, 50-60 Hz
Protection class: IP65, BS EN 60529
Mains supply voltage fluctuations not to exceed +/- 10% of nominal
Transient over voltage IEC 60664 Class II
Pollution degree 2, IEC 60664
Overall controller with gaskets fitted to valve connections
Contact rating reed relay (alarm contact) : max. 300 V, 0.5 A, 10 W
Power rating: 6 W
Instruction book
24 2920 7083 21

Related product manuals