Configure a company network (LAN) connection
Ask your IT department to generate a fixed IP address in your company’s network.
That IP address will be excluded from the DNS server, so it will be reserved for the
controller.
Also get the correct Gateway and Subnet mask settings. For example:
IP = 10.25.43.200
Gateway = 10.25.42.250
Subnet mask = 255.255.254.0
Connect the controller to the company's network (LAN) by using a UTP cable (min. CAT 5e).
Adapt the network settings in the controller:
Go to Main Menu
Instruction book
36 APF221384

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco G 160 VSD and is the answer not in the manual?

Atlas Copco G 160 VSD Specifications

General IconGeneral
Compressor TypeRotary Screw
Power Output160 kW
Maximum Pressure13 bar
Weight740 kg (1631 lbs)
Dimensions (L x W x H)1930 x 1150 x 1550 mm (76 x 45 x 61 in)
Free Air Delivery21.7 - 44.2 l/s (46 - 93 cfm)
Working Pressure4-10 bar (58-145 psi)
Installed Motor Power160 kW
Pressure7 - 13 bar
Motor Power160 kW
Power Supply400 V / 50 Hz