4.5 Quality of safety components
When installing a remote emergency button, the following B10d values are advised:
Emergency stop button: 500 000
4.6 Installation instructions for cubicle fan
Description
The fan must be installed on the cubicle roof with 8 bolts 0147 1963 08 as follows:
Take off the top of the fan assembly (fan stays).
Mount the fan with 8 bolts to the roof as shown in figure A (the fan is made invisible to show
the bolt positions).
Reinstall the top.
Connect the fan cable as shown in figure B once the dummy connector is removed. The
dummy connector is required to allow a qualification run at the end of the assembly line.
Figure A