9 Technical data
9.1 Readings on display
Important
The readings are valid when operating under reference conditions. See the
section Reference conditions.
Normally the main display is shown (see the section Function keys), indicating
the actual air outlet pressure and the actual compressor status. The arrow down
key allows the operator to call up other information such as actually measured
pressures and temperatures.
Important readings
Compressor outlet pressure bar(e) (psig) Depends on programmed
unloading and loading
pressures
Pressure drop over air filters bar Below 0.05
Pressure difference over oil separator bar Below 0.8
Oil injection pressure at the compressor elements bar(e) (psig) Depends on programmed
unloading and loading
pressures
Compressor outlet temperature, air-cooled Pack compressors ˚C Approx. 28
Cooling air inlet temperature of Pack compressor ˚C Below 46
9.2 Reference conditions
Reference conditions
Absolute inlet pressure bar(a) 1
Relative air humidity % 0
Air inlet temperature ˚C 20
Nominal working pressure See Compressor data
Cooling medium inlet temperature ˚C 20