11 Technical data
11.1 Readings on display
Display of Elektronikon regulator
Elektronikon II regulator
Important
The readings mentioned below are valid under the reference conditions (see section
Reference conditions and limitations).
Reference Reading
Air outlet pressure Depends on the setpoint (desired net pressure).
Compressor element
outlet temperature
Approx. 60 ˚C (108 ˚F) above ambient temperature.
Dewpoint temperature Approx. 4 ˚C (39 ˚F).
Cooling water outlet
temperature (on water-
cooled compressors)
Approx. 50 ˚C (122 ˚F).
11.2 Electric cable size
Attention
Local regulations remain applicable if they are stricter than the values proposed below.
The voltage drop must not exceed 5% of the nominal voltage. It may be necessary to use
cables of a larger size than those stated to comply with this requirement.
Use the original cable entry. See section Dimension drawings.
The voltage on the compressor terminals must not deviate more than 10% of the nominal
voltage.