3.24 Saved data menu
Control panel
Function
To call up some compressor data saved by the regulator. These data are:
Last shut-down data
Last emergency stop data
Procedure
Starting from the Main screen:
Press the key ‘Menu’ (F1).
Press the arrow down key (1) until the option ‘Saved Data’ is followed by a horizontal arrow.
Press the tabulator key (2) to activate the menu.
The list of last shut-down and emergency stop cases is shown.
Scroll through the items to select the desired shut-down or emergency stop item.
Press tabulator key (2) to find the date, time and other data reflecting the status of the compressor when
the last shut-down occurred.
3.25 Programmable settings
Compressor/motor
Minimum
setting
Factory
setting
Maximum
setting
Set-point 1/2
GA VSD Workplace bar(e) 4 7 13
GA VSD Workplace psig 58 100 188
GA VSD Full-Feature bar(e) 4 7 12.8
GA VSD Full-Feature psig 58 100 186
Indirect stop level bar 0.1 0.3 1
Indirect stop level psi 1.45 4.35 14.5
Direct stop level bar 0.3 1 1.5
Direct stop level psi 4.35 14.5 21.8
Proportional band % 6 10 15