- Press the emergency stop button, switch off the voltage and disconnect the compressor
from the mains.
- Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
- On water-cooled compressors:
Isolate and disconnect the water system from the cooling water net.
Drain the water circuit.
- Drain the oil.
- Drain the condensate circuit and disconnect the condensate piping from the condensate
net.