EasyManua.ls Logo

Atlas Copco GA 75 VSD

Atlas Copco GA 75 VSD
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Warranty - Product Liability
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts is not covered
by Warranty or Product Liability.
Service kits
For overhauling or carrying out preventive maintenance, service kits are available (see section Service kits).
Service contracts
Atlas Copco offers several types of service contracts, relieving you of all preventive maintenance work.
Consult your Atlas Copco Customer Centre.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
The local Atlas Copco Customer Centre may overrule the maintenance schedule, especially the service
intervals, depending on the environmental and working conditions of the compressor.
The longer interval checks must also include the shorter interval checks.
Service plans
Besides the daily and 3-monthly checks, the service operations are grouped in plans,
called service plans A, B, ... as specified in the schedule below.
Each plan has a programmed time interval at which all service actions belonging to that
plan are to be carried out. When reaching the interval, a message will appear on the screen
indicating which service plans are to be carried out; see section Status data menu. After
servicing, the intervals must be reset; see section Service menu.
Preventive maintenance schedule
General
Period Operation
Daily Check oil level.
Check readings on display.
Check air filter service indicator.
On water-cooled compressors: check for cooling water flow.
3-monthly Check coolers, clean if necessary.
On compressors with internal dryer: check condenser of dryer and clean if necessary.
Remove air filter element and inspect. If necessary, clean using an air jet and inspect.
More frequently when operating in a dusty atmosphere.
Replace damaged or heavily contaminated elements.
Check that condensate is discharged when pressing the test button on top of the electronic
water drain.
Instruction book
90 2920 1634 04

Table of Contents