Climatic exposure open air open air
Status of neutral (TT or NT) earthed earthed
Status of neutral (IT) (optional) insulated insulated
Engine 4) Standard ISO 3046 ISO 3046
ISO 8528-2 ISO 8528-2
Type PERKINS 1104C-44TG3/TG2 1104C-44TG3/TG2
Rated net output 54 kW 60 kW
rating type acc. ISO 3046-7 ICXN ICXN
Coolant coolant coolant
Combustion system direct injection direct injection
Aspiration turbo charged turbo charged
Number of cylinders 4 4
Swept volume 4.41 l 4.41 l
Speed governing mechanical / electronic mechanical / electronic
Governor type (optional) electronic with TG2 electronic with TG2
Capacity of oil sump (initial fill) 8.5 l 8.5 l
Capacity of cooling system 12.6 l 12.6 l
Electrical system 12 Vdc 12 Vdc
Emission compliance EU stage II EU stage II
Maximum premissible load factor of PRP during 24h period 80% 80%
Alternator 4) Standard IEC34-1 IEC34-1
ISO 8528-3 ISO 8528-3
Make Leroy Somer Leroy Somer
Model LSA43.2 M45 LSA43.2 M45
Rated output, class H temperature rise 60 kVA 71 kVA
rating type acc. ISO 8528-3 BR 125/40°C BR 125/40°C
Degree of protection (IP index acc. NF EN 60-529) IP 23 IP 23
Insulation stator class H H
Insulation rotor class H H
Number of wires 12 12