Parameters, relays and events 
9836 3043 01    25 (36) 
Safety current 
monitoring error 
The torque measured by the torque 
transducer is inconsistent with the 
torque estimated from the measured 
current. 
Try to modify the Pset settings 
regarding speed and first target 
settings. If problem persists, 
please contact the Atlas Copco 
service representative. 
DC voltage too high or too low: battery 
failure. May also occur sporadically 
when battery is approaching low level. 
May occasionally be due to internal 
electronics in the tool misjudging 
battery alarm level. 
Replace the battery. Contact the 
Atlas Copco service 
representative and send back 
battery to Atlas Copco (do not 
reuse it if faulty!). If battery is 
OK tool electronics must be 
analyzed. 
Tool internal error - 
Service tool 
Diode (LED) board in ST tool 
disconnected. Various internal errors 
for STB. Tool service needed. 
Acknowledge the event. 
Service the tool. 
Error condition 
detected by software 
An unexpected error condition was 
detected in software.  
Power Focus: The probable cause is 
that an external application has started 
too many subscriptions. 
STB: Software error. May or may not 
be auto repairable. 
Power Focus: Close external 
programs connected to Power 
Focus. 
STB: If the problem occurs 
frequently, please contact 
Market Support. 
SW function not 
available for this tool 
type 
This SW function is not available for 
this tool type 
Change to the correct tool type.