- 34 -
TURNING REGENERATION BACK TO AUTO
Machine is not running:
Power the controller down. At next power up, the DPF
Regeneration settings will be back to default, and an
Automatic DPF Regeneration will take place at the
soonest appropriate moment.
Machine is running:
Press the Settings View Button
Enter the '1000 GENERAL SETTINGS' menu
Scroll one line down and Enter the ‘1140 ECU DPF
REGENERATION’ menu
Scroll down and Enter the 'MODE' parameter
Scroll down and Enter the 'AUTOMATIC' setting
Press the Back button 3 times to get back to the Main
view
Also make sure parameter '1142 ECU DPF REGEN-
ERATION ENABLE' is set to "ON"
DPF Regeneration setting will now be AUTOMATIC
DPF REGENERATION.
Customer Level can now select between AUTO
Regeneration & INHIBIT Regeneration, as long as the
controller is not powered down (after power down, it will
fall back to its default DPF Regeneration settings, and a
Service Level is needed to go back to Inhibit DPF
Regeneration).
FORCE DPF REGENERATION
Machine is running:
Press the Settings View Button
Enter the '1000 GENERAL SETTINGS' menu
Go to parameter '1130 STATIONARY REGENERA-
TION'
Scroll to Enable and change to "ON"
SERVICE REGENERATION
Machine is running:
Press the Settings Menu
Enter the '7000 ENGINE' menu
Go to parameter '7140 SERVICE REGENERA-
TION'
Scroll to Enable and change to "ON"
SETTINGS
For buttons to be used see “Control Panel”
Acknowledge an Alarm
If an alarm becomes active, for example a Low Fuel Level
Warning:
then this alarm can be acknowledged by pressing the
ENTER button. If the fuel level is still low, the view
will change to:
As soon as the fuel level is higher than the warning level,
the alarm icon will automatically disappear.
As long as there is an alarm icon in the middle of the
bottom part of the view, all active acknowledged /
Unit will not regenerate if soot level is not
high enough.
Unit will not regenerate if soot level is not
high enough.