Alarmcode Alarmtext Failclass Trigger
1231 FUEL FILL CHECK Warning Xc
1503 INITIAL OVERHAUL REQUIRED Warning Xc
1522 MINOR OVERHAUL WITHIN ** H Warning Xc
1523 MINOR OVERHAUL WITHIN ** D Warning Xc
1524 MINOR OVERHAUL REQUIRED Warning Xc
1552 MAJOR OVERHAUL WITHIN ** H Warning Xc
1553 MAJOR OVERHAUL WITHIN ** D Warning Xc
1554 LOAD PREVENTION - FIRE RISK Inhibit Load Xc
1558 COMP. OIL CHANGE WITHIN ** H Warning Xc
1559 COMP. OIL CHANGE WITHIN ** D Warning Xc
2000 EMERGENCY STOP INPUT Shutdown Xc
2040 REMOTE EMERGENCY STOP Shutdown Xc
2070 COOLANT LEVEL LOW WARNING Warning Xc
2080 COOLANT LEVEL LOW SHUTDOWN Shutdown Xc
2090 ΔP AIRFILTERS HIGH Warning Xc
2100 NO PROJECTFILE DOWNLOADED Warning Xc
2752 NAM OILTRONIX BYPASS CIRCUIT Shutdown After Stop Xc
2762 NAM OILTRONIX CLOSED CIRCUIT Shutdown After Stop Xc
2772 NAM AIRXPERT OPENED CIRCUIT Shutdown Xc
2782 NAM AIRXPERT CLOSED CIRCUIT Shutdown Xc
3000 FUEL LEVEL LOW WARNING Warning Xc
3010 FUEL LEVEL LOW SHUTDOWN Controlled Stop Xc
3020 FUEL LEVEL SENSOR CIRCUIT Warning Xc
3050 VESSEL PRESSURE HIGH WARNING Controlled Stop Xc
3060 VESSEL PRESSURE HIGH SHUTDOWN Shutdown Xc
3070 VESSEL PRESSURE SENSOR CIRCUIT Shutdown Xc
3120 REGULATING PRESSURE SENSOR CIRCUIT Shutdown Xc
3170 AIR DISCHARGE PRESSURE SENSOR CIRCUIT Warning Xc
3320 INLET PRESSURE SENSOR CIRCUIT Shutdown Xc
3450 BATTERY LOW ALARM Indication Xc
3460 BATTERY HIGH ALARM Warning Xc
3660 FIRE RISK - CHECK OILSTOPVALVE Shutdown Xc
3680 OSV PRESSURE SENSOR CIRCUIT Controlled Stop Xc
3720 INTERSTAGE PRESSURE SENSOR CIRCUIT Warning Xc
4000 L.P. ELEMENT TEMPERATURE HIGH Warning Xc
4010 L.P. ELEMENT TEMP. ALARM 2 Controlled Stop Xc
4020 L.P. ELEMENT TEMP. ALARM 3 Shutdown Xc