- 28 -
CONTROL PANEL XC2002™ MODULE
The Xc2002™ module is located inside the control panel.
This module will carry out all necessary tasks to control
and protect the compressors, regardless of the use of the
compressor.
This means that the Xc2002™ module can be used for
several applications.
Pushbutton and LED functions
Following pushbuttons are used on the Xc2002™
Following LED´s are used on the Xc2002™
Reference Name
1Emergency stop
2 Xc2002™ module
3 Pressure gauge
ON/OFF Power ON/OFF switch
ENTER: Used to select and confirm changed
settings in the Parameters list.
BACK: Is used to leave the Alarm pop-up
window, to leave the Parameter list and to
leave menus without change
UP: Is used to scroll through the display
information and to adjust parameter values
upwards.
DOWN: Is used to scroll through the display
information and to adjust parameter values
downwards.
START: Is used to start the unit in Manual
Mode.
LOAD: Is used to load the compressor
REMOTE LOAD: Is used to activate the
remote load function of the compressor
STOP: Is used to stop the unit in Manual or
Remote Load Mode. When the unit is stopped
with the stop button in Remote Load Mode, it
will automatically go to Manual Mode.
To connect remote function, contact Atlas
copco.
Reference Name
1 Power:
Power OK indicator.
2 Alarm:
Flashing: Active, non-acknowledged
alarm(s) present.
Steady: Active, acknowledged alarm(s)
present.
3 Remote:
Indicates if unit is in Remote mode.
4 Load:
Indicates if the compressor is loaded.
5 Run:
Indicates if running feedback is present.