- 36 -
FAULT CODES
There are several parameters that are continuously
watched.When one of these parameters exceeds its
specified limit the compressor will react depending the
present status of the control box. The message displayed
can be a warning, a shut down or a start failure.
Display text Warning Shutdown Wait to start
Engine Fault Codes (Canbus SAE J1939):
Engine Sensor Failure X X
Fuel Pressure Low X X
Coolant Temperature High X X
Injector Failure X X
Oil Pressure low X X
Air Inlet Temperature High X
Turbo Boost Pressure High X X
Oil Temperature High X
Water in Fuel X
Xc2002 Fault Codes:
Sensor Failure (Fuel Level, Vessel Pressure, Regulating Pressure,
Element Temperature)
X
Can SAE J1939 Communication Failure X
Overspeed X
Fuel Level Low X X
Element Temperature High X X
Coolant Level Low X
Battery Voltage Low X
Battery Charge Failure X
Check Airfilters X
Start Failure X
Stop Failure X
Service Timer 1 X
Service Timer 2 X
Emergency Stop X

Table of Contents