- 33 -
XC2002™ MENU DESCRIPTION
Status Display (pop-up window)
In case special statuses are entered, a pop-up window will
automatically be entered for as long as the status is active.
The background screen is not updated when the status
pop-up window is active.
These special statuses are:
If a special status has elapsed, the active view will be
entered again automatically.
If an Alarm comes up, the Alarm Display is shown.
Alarm Display (pop-up window)
In case an Alarm occurs, a pop-up window will
automatically be displayed for as long as the alarm is
active, no matter which view is active. The flashing red
alarm LED will light up. The alarm icons will be shown
together with an acknowledgement check-box. Push the
ENTER button to acknowledge the alarm. When the
alarm has been acknowledged, a V-marking will appear in
the check-box and the red alarm LED will light up
continuously.
An Alarm Display can always be left by pushing the
BACK button.
If more than one alarm occurs, it is possible to scroll
through the alarm messages with the UP and DOWN
pushbuttons. The most recent alarm will be placed on the
bottom of the list (meaning the older alarm stays at the
display when a new alarm comes up).
List of possible alarms:
If a shutdown comes up, the Shutdown Display is shown.
LOG list
The unit will keep an event log of the latest 15 events.
Events are:
• Shutdowns
• Warnings
• Service Timer 1/2 reset
• Unit type changes
Together with each event, the running hours at the time of
the event will be stored.
Fail Classes
All activated alarms of the Xc2002™ have their own
predefined fail class.
All alarms are enabled according to one of these three
statuses:
• disabled alarm, no supervision of alarm (OFF)
• enabled alarm, supervision of alarm all the time (ON)
• running alarm, only supervision when the machine is
running (RUN)
•PREHEAT
•WAIT
• COOLDOWN
• DIAGNOSTICS
• LOAD / NO LOAD
Fuel 12%
00000.h
An alarm should always be acknowledged
before solving the problem that causes the
alarm.
1. LOW OIL PRESSURE
2. HIGH COOLANT
TEMPERATURE
3. CHARGING
ALTERNATOR
4. XDEC
5. LOW FUEL LEVEL
6. LOW COOLANT LEVEL
11. SERVICE TIMER 1
12. SERVICE TIMER 2
13. ELEMENT
TEMPERATURE
14. ALARM
!
Reference Name
1 Controller Type
2 Event Number
3 Event
4 Time of event
Xc 2002 EVENT LOG #02
Element Temp. 2
Time: 000000 h
(1) (2)
(3) (4)