Light Source | Xenon Arc Lamp |
---|---|
Wavelength Range | 290 - 800 nm |
Irradiance | Adjustable |
Irradiance Control | Automatic |
Temperature Control | Yes |
Humidity Control | Yes |
Temperature Range | Ambient to 100°C (black standard temperature) |
Relative Humidity Range | 10% - 75% RH (depending on temperature) |
Test Area Dimensions | 480 x 320 mm |
Control | Microprocessor-based |
Cooling System | Air Cooled |
Standards Met | ISO, ASTM, DIN, SAE and others (depending on configuration) |
Power Supply | 230 V, 50/60 Hz |
Explains safety symbols used in the manual and on the equipment for hazard identification.
Provides guidelines for authorized/unauthorized usage and safety during commissioning and disposal.
Lists the components included with the SUNTEST XLS and SUNTEST XLS+ models.
Lists the materials used for packing the equipment for safe transport.
Details the climatic conditions and installation requirements for optimal equipment performance.
Describes the features, controls, and operation of the SUNTEST XLS model.
Describes the features, controls, and operation of the SUNTEST XLS+ model.
Identifies common components on the rear side and test chamber of both SUNTEST models.
Explains how radiation is generated, filtered, and how specimens are exposed to light.
Describes the airflow systems for cooling the test chamber and the Xenon lamp.
Presents graphs showing spectral distributions with various optional filters.
Details the integrated sensors for irradiance, temperature, and data transfer in the XLS+.
Lists the safety and protection features incorporated into the equipment for operational safety.
Highlights important safety notices and markings present on the equipment for user awareness.
Lists various sensors for measurement and calibration purposes.
Details different filters for spectral distribution adjustments and sample protection.
Includes options like the water-cooled sample table for specific material testing.
Provides covering sheets for direct visual comparison of test areas.
Details the flooding device with undercarriage and tub for cyclic wetting of specimens.
Describes the SunCool unit for reducing test chamber temperature by 12-16°C.
Instructions for installing the sample table, including safety precautions regarding UV radiation.
Steps for assembling the radiation system, including safety warnings about heat and electrical shock.
Procedure for opening the equipment's assembly compartment, with safety alerts for hot components.
Detailed steps for cleaning and installing the optical filters, with cut hazard warnings.
Instructions for cleaning and installing the Xenon lamp into its socket.
Steps for cleaning and installing the reflecting mirrors for uniform illumination.
Instructions for closing the assembly compartment after installation and securing it.
Procedures and safety warnings for connecting the equipment to the appropriate power supply.
Steps for setting up the equipment before operation, including safety notices.
A step-by-step guide for performing a standard weathering test.
How to use optional accessories to enhance testing capabilities and material analysis.
Describes how to operate the basic SUNTEST XLS model using its controls.
Explains the operation of the SUNTEST XLS+ using its advanced program controller.
How to transfer test data to a PC or printer via the RS 232 serial port.
Instructions for safely shutting down the equipment, including cooling procedures and specimen removal.
Procedure for calibrating irradiance using the XenoCal Global-Sensor.
Procedure for calibrating irradiance using the Radialux Global Sensor.
Procedure for calibrating the black standard temperature for accurate measurements.
General cleaning instructions for the equipment and its outer surfaces.
Instructions for cleaning the reflector to ensure uniform illumination of the test chamber.
Cleaning procedures for optical filters, Xenon lamp, and reflecting mirrors.
Instructions for cleaning and maintaining the air filters to prevent dust ingress.
Lists consumables and spare parts available for replacement by the user.
Recommendations for ensuring the proper condition of systems through regular maintenance.
Information on obtaining spare parts and related documentation from the manufacturer.